Refine Your Search

Topic

Author

Affiliation

Search Results

Journal Article

Ducted Fuel Injection: Effects of Stand-Off Distance and Duct Length on Soot Reduction

2019-04-02
2019-01-0545
Ducted fuel injection (DFI) has been shown to be an effective method to significantly reduce soot formation in mixing controlled compression ignition (MCCI) diesel combustion. This reduction has been demonstrated in both combustion vessels and in an optical engine. The mechanisms driving the soot reduction are to date not fully understood. Optimal duct configurations are also not immediately evident. The objective of this study is to show the effects of two geometric variables, namely distance from fuel injector orifice exit to duct inlet (0.1-6 mm) for a 2x14 mm duct, and duct length variation (8-14 mm) at a given stand-off distance of 0.1 mm. A 138 μm on-axis single-orifice injector operated at 100-250 MPa was used in a heated, continuous flow, constant pressure vessel with optical access.
Journal Article

Fuel Effects on the Propensity to Establish Propagating Flames at SPI-Relevant Engine Conditions

2021-04-06
2021-01-0488
In order to further understand the sequence of events leading to stochastic preignition in a spark-ignition engine, a methodology previously developed by the authors was used to evaluate the propensity of a wide range of fuels to establishing propagating flames under conditions representative of those at which stochastic preignition (SPI) occurs. The fuel matrix included single component hydrocarbons, binary mixtures, and real fuel blends. The propensity of each fuel to establish a flame was correlated to multiple fuel properties and shown to exhibit consistent blending behaviors. No single parameter strongly predicted a fuel’s propensity to establish a flame, while multiple reactivity-based parameters exhibited moderate correlation. A two-stage model of the flame establishment process was developed to interpret and explain these results.
Technical Paper

The Effect of a Diesel Oxidation Catalyst and a Catalyzed Particulate Filter on Particle Size Distribution from a Heavy Duty Diesel Engine

2006-04-03
2006-01-0877
The effect of a Johnson Matthey catalyzed continuously regenerating technology™ (CCRT®) filter on the particle size distribution in the raw exhaust from a 2002 Cummins ISM-2002 heavy duty diesel engine (HDDE) is reported at four loads. A CCRT® (henceforth called DOC-CPF) has a diesel oxidation catalyst (DOC) upstream (UP) of a catalyzed particulate filter (CPF). The particle size data were taken at three locations of UP DOC, downstream (DN) DOC and DN CPF in the raw exhaust in order to study the individual effect of the DOC and the CPF of the DOC-CPF on the particle size distribution. The four loads of 20, 40, 60 and 75% loads at rated speed were chosen for this study. Emissions measurements were made in the raw exhaust chosen to study the effect of nitrogen dioxide and temperature on particulate matter (PM) oxidation in the CPF at different engine conditions, exhaust and carbonaceous particulate matter (CPM) flow rates.
Technical Paper

Ducted Fuel Injection: Confirmed Re-entrainment Hypothesis

2024-04-09
2024-01-2885
Testing of ducted fuel injection (DFI) in a single-cylinder engine with production-like hardware previously showed that adding a duct structure increased soot emissions at the full load, rated speed operating point [1]. The authors hypothesized that the DFI flame, which travels faster than a conventional diesel combustion (CDC) flame, and has a shorter distance to travel, was being re-entrained into the on-going fuel injection around the lift-off length (LOL), thus reducing air entrainment into the on-going injection. The engine operating condition and the engine combustion chamber geometry were duplicated in a constant pressure vessel. The experimental setup used a 3D piston section combined with a glass fire deck allowing for a comparison between a CDC flame and a DFI flame via high-speed imaging. CH* imaging of the 3D piston profile view clearly confirmed the re-entrainment hypothesis presented in the previous engine work.
Technical Paper

Numerical Study of a Six-Stroke Gasoline Compression Ignition (6S-GCI) Engine Combustion with Oxygenated Fuels

2024-04-09
2024-01-2373
A numerical investigation of a six-stroke direct injection compression ignition engine operation in a low temperature combustion (LTC) regime is presented. The fuel employed is a gasoline-like oxygenated fuel consisting of 90% isobutanol and 10% diethyl ether (DEE) by volume to match the reactivity of conventional gasoline with octane number 87. The computational simulations of the in-cylinder processes were performed using a high-fidelity multidimensional in-house 3D CFD code (MTU-MRNT) with improved spray-sub models and CHEMKIN library. The combustion chemistry was described using a two-component (isobutanol and DEE) fuel model whose oxidation pathways were given by a reaction mechanism with 177 species and 796 reactions.
Technical Paper

Measurement of Hydrogen Jet Equivalence Ratio using Laser Induced Breakdown Spectroscopy

2024-04-09
2024-01-2623
Hydrogen exhibits the notable attribute of lacking carbon dioxide emissions when used in internal combustion engines. Nevertheless, hydrogen has a very low energy density per unit volume, along with large emissions of nitrogen oxides and the potential for backfire. Thus, stratified charge combustion (SCC) is used to reduce nitrogen oxides and increase engine efficiency. Although SCC has the capacity to expand the lean limit, the stability of combustion is influenced by the mixture formation time (MFT), which determines the equivalence ratio. Therefore, quantifying the equivalence ratio under different MFT is critical since it determines combustion characteristics. This study investigates the viability of using a Laser Induced Breakdown Spectroscopy (LIBS) for measuring the jet equivalence ratio. Furthermore, study was conducted to analyze the effect of MFT and the double injection parameter, namely the dwell time and split ratio, on the equivalence ratio.
X